The Tool Crib Regulation Facts

Home of The Tool Crib The world’s first Professional Aviation Tool Exchange

The Tool Crib · Regulation facts

FAA and EASA tooling requirements The Tool Crib helps to assist in meeting

The tooling-related regulations behind our membership benefits, grouped by audit surveys of tooling, tooling control and calibration, and the capabilities list.

Audit surveys of tooling

What auditors and inspectors check when tooling is borrowed: documented procedures, calibration and records. Every member also keeps a standard Internal Quality Questionnaire (IQQ) on file for your supplier audit.

RegulationApplies toRequirementHow it helps to assist in meeting the requirement
14 CFR 145.211(c)(1)(viii)FAA Part 145 repair stationsThe quality control manual must describe procedures for calibrating measuring and test equipment, including calibration intervals.Each calibrated listing records the calibration date, interval, laboratory and certificate, ready for your audit file.
FAA AC 145-9, ¶4-2.e(3)(e)–(f)Repair station manualsFor leased or rented equipment, the manual should cover the lease or rental process, the person responsible for the programme, required calibration or verification, and how the station ensures the equipment is in place and under its control when work is performed.The Tool Crib’s request, calibration and return process and the Tooling Availability Agreement give you a documented process to reference.
EASA / UK Part-145, 145.A.40(b)Part-145 maintenance organisationsTools and test equipment must be controlled and calibrated to an officially recognised standard, with calibration records and traceability to the standard kept.Calibration certificates travel with every calibrated listing, giving auditors the traceability record.
Tooling control and calibration

Calibrated tooling is only listed while its calibration is current, and the Tooling Availability Agreement documents how borrowed tooling is under your control.

RegulationApplies toRequirementHow it helps to assist in meeting the requirement
14 CFR 145.109(a)FAA Part 145 repair stationsHave the equipment, tools and materials needed for the work you are rated for, located on the premises and under the repair station’s control when the work is done.The agreement records the source of the tooling and the loan terms; the tool is shipped to you and is under your control for the job.
14 CFR 145.109(b)FAA Part 145 repair stationsTest and inspection equipment and tools used for airworthiness determinations must be calibrated to a standard acceptable to the FAA.Calibrated tooling drops off the network the day its calibration expires; owners are reminded 30 days before.
14 CFR 145.109(c)FAA Part 145 repair stationsEquipment, tools and materials must be those recommended by the manufacturer, or at least equivalent and acceptable to the FAA.Search by the OEM tool part number specified in the maintenance data.
FAA AC 145-9, ¶4-2.dRepair station manualsIf you do not own equipment, your manual should describe how it is obtained (for example by lease or rental), who calibrates leased tools, and how calibration or verification is completed before use.Calibration status and certificates are visible before you request a tool.
14 CFR 43.13(a)Everyone who performs maintenance — including independent A&P mechanicsUse the tools, equipment and test apparatus necessary to complete the work to accepted industry practices; where the manufacturer recommends special equipment, use it or an equivalent acceptable to the FAA.Access to the manufacturer’s special tooling when the job calls for it.
14 CFR 121.367(b)Part 121 air carriersThe maintenance programme must ensure adequate facilities and equipment are provided for the work.Documented access to tooling for scheduled and AOG work.
EASA / UK Part-145, 145.A.40(a)Part-145 maintenance organisationsHave available and use the necessary equipment and tools; use the manufacturer’s specified tool unless the authority agrees an alternative. Tools must be permanently available, except those used so infrequently that permanent availability is not necessary — such cases must be detailed in an exposition procedure.The agreement helps to assist in meeting the exposition procedure for infrequently used tooling.
Capabilities list

Add articles to your capability list knowing the tooling for them is available to you.

RegulationApplies toRequirementHow it helps to assist in meeting the requirement
14 CFR 145.215(c)Repair stations with limited ratingsAdd an article to the capability list only after a self-evaluation shows the equipment (with housing, facilities, material, technical data, processes and trained personnel) is in place; keep that documentation on file.The agreement and the tool listings help to assist in meeting the equipment part of your self-evaluation.
14 CFR 145.209(d)(2)Repair station manualsThe manual must contain the procedures for that self-evaluation, including methods, frequency, and how results are reported for review and action.Name The Tool Crib as an equipment source in your self-evaluation procedure.

Many other authorities base their maintenance organisation rules on FAA Part 145 or EASA Part-145; members should check their own authority’s equivalent paragraph. Acceptance is always decided by your authority — your FAA principal inspector or competent authority. The agreement helps to assist in meeting the requirements; it is not an approval, and your manual or exposition must describe how borrowed tooling is obtained, controlled and calibrated. Summaries are paraphrased; refer to the current regulation text.

Visit The Tool Crib Try the demo

The Tool Crib